Lined Y Type Strainer Double Flanged End Rating 150 Class
Fluoropolymer Lined strainers are well suited for use in removing suspended or waste solids from extremely corrosive or high-purity fluid streams. They help prevent damage to sensitive downstream process components such as pumps, valves, instruments, and spray nozzles. When compared with PVC, CPVC, or polypropylene units, they provide superior corrosion resistance, as well as a higher operating temperature range.
Design & Testing Standard of PTFE, PFA, FEP, Teflon® Lined Y Type Strainer: | ||
Design Standard |
: |
ASME B 16.34 |
Inspection & Testing Standard |
: |
BS EN ISO 12266 – I (BS 6755 – I) |
Flange To Flange Distance |
: |
Manufacturing Standard |
End Connection |
: |
Flanged End to ANSI B 16.5, 150 |
BS 10 Table D / E | ||
Manufacturing Size Range |
: |
1″(DN25) to 6″(DN150) |
Pressure Rating of Valve |
: |
PN 10 |
Dimension Table
Size(NB) | L±5 | OD | H | T |
25 MM | 190 | 108 | 128 | 17 |
40 MM | 265 | 127 | 240 | 17 |
50 MM | 290 | 153 | 210 | 19 |
65 MM | 320 | 178 | 240 | 22 |
80 MM | 350 | 191 | 250 | 23 |
100 MM | 415 | 230 | 310 | 23 |
150 MM | 520 | 280 | 388 | 25 |
200 MM | 605 | 343 | 585 | 26 |
Material Specification
NO. | DESCRIPTION | QTY. | MATERIAL |
1 | SHELL | 1 | CS / SS +3 mm THK. PPH/PVDF/FEP/PFA LINING. |
2 | SEAT | 1 | INTEGRAL PVDF/FEP/PFA |
3 | OUTER TUBE | 1 | PTFE |
4 | FILTER TUBE | 1 | ETFE-MESH SIZE 40 |
5 | INNER TUBE | 1 | PTFE |
6 | SHELL COVER | 1 | CI / DI + PVDF/FEP/PFA LINING. |
7 | FASTENERS | – | SS / STEEL PLATED |
Notes
- 1. Manufacturing Standards
Design | : | Manufacturer’s Standard |
Face To Face Dimension | : | Manufacturer’s Standard. |
- 2. Spark Test 15 KVDC
- 3. Standard Resin Specifications For Lining
PTFE | : | ASTM D 1457 |
PVDF | : | ASTM D 3222 |
PFA | : | ASTM D 3418 |
FEP | : | ASTM D 2116 |
- 4. Material
DI | : | ASTM A 395 |
CI | : | GRADED CASTING |